09_app_settings_light_system.pngImage Removed

Marso needs to know the relative positions of your lights to the sensor, as well as the order they will be triggered when capturing.

Panel
panelIconId1f516
panelIcon:bookmark:
panelIconText🔖
bgColor#DEEBFF

If you have not yet measured the lights on your capture system, please refer to this guide.

Start off by launching the settings window by going to :

File -> Settings

Click Lights Setup to open the Light Systems Dialog.

New Light Systems can be created from the settings menu, or when configuring a job.

09_app_settings_light_system.pngImage Added

New Light System Configuration

The leftmost upper left panel is used panel to create new light systems.

Existing ones can be selected in the centre upper right panel, and the light positions for the selected system will displayed in the rightmost panelvisualization below.

09_new_light_system.pngImage Removed10_new_light_system.pngImage Added

Light positions are specified in meters, and are relative to the camera sensor, in the coordinate system shown below.

If your camera is in portrait or upside down, then Y ‘up’ relates to real-world up.

CoordinateSystem_Front.png
CoordinateSystem_Back.png
Note

Your camera system must remain in the same orientation that you have used for the calibration image to maintain a consistent Light position relationship. It is okay if the internal gyroscope of the camera flips images landscape/portrait when shooting above the object.

Clicking the Add button creates a new row storing the light position once its XYZ coordinates have been entered. Each row should be populated and added in the order in which the lights will be turned on during a scan. If you have made a mistake during this process, or have the lights in the wrong order, select the incorrect row and use the remove button and start againto remove a row.

10_add_new_light.pngImage Removed11_add_new_light.pngImage Added

Once all light positions have been added, the Light System parameters can be named should be given a name, and saved by using the provided Name input field and the Save button positioned to its right.

11_save_light_system.pngImage Removed12_save_light_system.pngImage Added
Info

We have provided some example calibrations if you are having difficulties.


Loading a Light System

Similar to the exposure calibration, once the new Light System parameters have been saved, they will be stored and appear in the Light System Selection pane. Select the correct Light System for the current scanning setup used by selecting the corresponding row in the list, and clicking the Save button in the bottom right corner :

12_select_light_system.pngImage Removed

The selected Light System will now be set as the default and appear in the Settings dialog:

14_save_app_settings.pngImage Removed

Pressing “Save” in the Application Settings dialog completes and stores the environment setup for processing future scans.of the panel.

Selecting a row will display it in the visualization This can be freely rotated to confirm the light system looks correct.

13_select_light_system.pngImage Added